IJSRP, Volume 11, Issue 1, January 2021 Edition [ISSN 2250-3153]
Dr. Rutuja S. Kamble, Prof. A. B. Pandit
Abstract:
The performance of a tailor-made design of membrane module was studied at different aeration intensities (120, 240 and 480 L/h) to comprehend the concept of membrane fouling control using aeration. The effect of aeration on membrane fouling control is evaluated by observing the structure of cake layer, the quality of effluent and the flux of filtrate obtained.